Effects of Microwave and Light Emitting Diode as Disinfection Methods on the Color Stability of Polymethyl Methacrylate and Polyamide Denture Base Resins Disinfection Effects on Color of Dentures
Main Article Content
Abstract
Objective: To determine the effects of disinfection through microwave (MW) and LED disinfection on color stability of Polymethyl Methacrylate (PMMA) and Polyamide (PA) denture base resins.
Methodology: A total of 30 specimens of 25x25x5mm dimensions were fabricated in a split mold of stainless steel, which was categorized into 2 groups Polymethyl Methacrylate (PMMA) and Polyamide (PA). These were further differentiated into groups of no exposure (Group A) or microwave (group B) and LED (group C) exposure. Primary color parameters were determined according to CIELab color space for all specimens once immediately after fabrication, using a spectrophotometer within the visible light range of 400 to 700nm. For group B & C, the specimens were exposed to disinfection regimens thrice a week for 4 weeks. After 4 weeks, the specimens were again examined. Data was statistically analyzed using one-way ANOVA and post hoc Tukey’s tests (SPSS ver 26), p <0.05.
Results: ANOVA for the PMMA presented no significant results in comparison with PA. On Post Hoc analysis of PA, a significant difference (0.006) was found between groups B and C. Color stability of PMMA remained unaffected statistically after disinfection, but color of PA was adversely affected by MW.
Conclusion: The denture base resins’ disinfection regimens did not significantly change color of PMMA. Total color change in PMMA according to NBS remained in the lower range of appreciable color change. For PA, MW disinfection is not feasible as it caused unacceptable color change of the PA base resin.
Article Details
Work published in JPMI is licensed under a
Creative Commons Attribution-NonCommercial 2.0 Generic License.
Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.
References
Alqutaibi AY, Baik A, Almuzaini SA, Farghal AE, Alnazzawi AA, Borzangy S, et al. Polymeric Denture Base Materials: A Review Polymers (Basel) 2023;15(15):3258 DOI: 10.3390/polym15153258
Rashid H, Sheikh Z, Vohra F Allergic effects of the residual monomer used in denture base acrylic resins Eur J Dent 2015;9(4):614-19 DOI: 10.4103/2F1305-7456.172621
Lee CJ, Bok SB, Bae JY, Lee HH Comparative adaptation accuracy of acrylic denture bases evaluated by two different methods Dent Mater J 2010;29(4):411-17 DOI: 10.4012/dmj.2009-105
Sampaio-Fernandes M, Galhardo J, Campos S, Oliveiro SJ, Reis-Campos JC, Stegun RC, et al. Color changes of two thermoplastic resins used for flexible partial dentures Comput Methods Biomech Biomed Eng Imaging Vis 2020;1-6 DOI: 10.1080/21681163.2020.1771617
Kostic M, Pejcic A, Igic M, Gligorijevic N Adverse reactions to denture resin materials Eur Rev Med Pharmacol Sci 2017;21(23):5298-305 DOI: 10.26355/eurrev_201712_13909
Kurt A, Erkose-Genc G, Uzun M, Sari T, Isik-Ozkol G The effect of cleaning solutions on a denture base material: elimination of Candida albicans and alteration of physical properties J Prosthodont 2018;27(6):577-83 DOI: 10.1111/jopr.12539
Brondani MA, Siqueira AR A critical review of protocols for conventional microwave oven use for denture disinfection Community Dent Health 2018;1-7 DOI: 10.1922/cdh_4372brondani07
Sousa TM, Farias OR, Batista AU, Medeiros ES, Santiago BM, Cavalcanti YW Effectiveness of denture microwave disinfection for treatment of denture stomatitis: a systematic review and meta-analysis Int J Dent Hyg 2021;19(1):62-77 DOI: 10.1111/idh.12477
Popescu MC, Bita BI, Tucureanu V, Vasilache D, Banu MA, Avram AM, et al. Superficial and inner examination of a microwave-irradiated dental acrylic resin and its metal-polymer interface Microsc Microanal 2018;24(1):49-59 DOI: 10.1017/S1431927618000089
Jaiswal P, Pande N, Banerjee R, Radke U Effect of repeated microwave disinfection on the surface hardness of a heat-cured denture base resin: an in vitro study Contemp Clin Dent 2018;9(3):446 DOI: 10.4103/ccd.ccd_271_18
Fortes CB, Collares FM, Leitune VC, Schiroky PR, Rodrigues SB, Samuel SM, et al. Effect of disinfection techniques on physical-mechanical properties of a microwave-activated acrylic resin Polímeros 2018;28(3):215-19 DOI: 10.1590/0104-1428.004616
Tsutsumi-Arai C, Arai Y, Terada-Ito C, Takebe Y, Ide S, Umeki H, et al. Effectiveness of 405-nm blue LED light for degradation of Candida biofilms formed on PMMA denture base resin Lasers Med Sci 2019;34:1457-64 DOI: 10.1007/s10103-019-02751-2
Al-Qarni FD, Goodacre CJ, Kattadiyil MT, Baba NZ, Paravina RD Stainability of acrylic resin materials used in CAD-CAM and conventional complete dentures J Prosthet Dent 2020;123(6):880-87 DOI: 10.1016/j.prosdent.2019.07.004
Zuo W, Feng D, Song A, Gong H, Zhu S Effects of organic-inorganic hybrid coating on the color stability of denture base resins J Prosthet Dent 2016;115(1):103-08 DOI: 10.1016/j.prosdent.2015.07.008
Arana-Correa BE, Sepulveda-Navarro WF, Florez FL, Urban VM, Jorge JH, Campanha NH Colour stability of acrylic resin denture teeth after immersion in different beverages Eur J Prosthodont Restor Dent 2014;22(2):56-61
Ozyilmaz OY, Akin C Effect of cleansers on denture base resins’ structural properties J Appl Biomater Funct Mater 2019;17(1):2280800019827797 DOI: 10.1177/2280800019827797
Bohra PK, Ganesh PR, Reddy MM, Ebenezar AR, Sivakumar G Color stability of heat- and cold-cure acrylic resins J Clin Diagn Res 2015;9(1):ZC12 DOI: 10.7860/JCDR/2015/11620.5400
Gruber S, Kamnoedboon P, Ozcan M, Srinivasan M CAD/CAM complete denture resins: An in vitro evaluation of color stability J Prosthodont 2021;30(5):430-39 DOI: 10.1111/jopr.13246
Motawea I, Gamal El Deen H, Eltayeb H Effect of denture cleansers on flexural strength, color stability, and surface roughness of flexible and microwave-cured acrylic resin Al-Azhar Dent J Girls 2017;4(3):311-23 DOI: 10.21608/adjg.2017.5272
Al-Thobity AM, Gad M, ArRejaie A, Alnassar T, Al-Khalifa KS Impact of denture cleansing solution immersion on some properties of different denture base materials: An in vitro study J Prosthodont 2019;28(8):913-19 DOI: 10.1111/jopr.12649
Hong G, Li Y, Ma J, Zheng Y The effects of different denture cleaning methods on surface roughness and hydrophobicity of denture base materials Dent Mater J 2018;37(5):842-49 DOI: 10.4012/dmj.2017-392
Machado AL, Giampaolo ET, Pavarina AC, Jorge JH, Vergani CE The effect of repeated simulated microwave disinfection on the strength of denture base resins J Prosthet Dent 2006;95(2):114-19 DOI: 10.1016/j.prosdent.2005.11.003
Ribeiro DG, Pavarina AC, Dovigo LN, Giampaolo ET, Vergani CE Effect of thermal cycling on the microhardness of resins used for denture bases and for direct relining Braz Dent J 2009;20(4):336-41 DOI: 10.1590/s0103-64402009000400010
Daneshkazemi AR, Jafari H, Karami Z Effect of denture cleansers on color stability of acrylic resins with different denture teeth Front Dent 2020;17(4):1-6 DOI: 10.18502/fid.v17i4.4646
Singh K, Thakur M, Bansal N, Saini M, Anuradha P Effects of denture cleansers on color stability, surface roughness, and hardness of denture base materials: A comparative in vitro study Indian J Dent Sci 2020;12(4):202-07 DOI: 10.4103/ijds.ijds_41_20
Amin FA, El Kholy MS, Ghanem A Color stability of two denture base materials immersed in a denture cleanser J Dent Health Oral Disord Ther 2018;9(1):36-42 DOI: 10.15406/jdhodt.2018.09.00331
Lee JH, Jo JY, Kim SC, Ahn JS Color stability of denture base resins containing an organic–inorganic hybrid coating Materials (Basel) 2017;10(10):1162 DOI: 10.3390/ma10101162
Bural C, Aktas E, Deniz G, Kiic HS Effects of oral cavity conditions on hardness, color stability, and water sorption of polyamide denture base material J Adv Prosthodont 2015;7(5):375-83 DOI: 10.4047/jap.2015.7.5.375
Polyzois GL, Tarantili PA, Frangou MJ, Andreopoulos AG Effect of glutaraldehyde disinfectant solutions on some properties of heat-cured acrylic resins Int J Prosthodont 2000;13(2):150-54
Zuo W, Song A, Zhu S The effects of oral rinsing agents on the color stability of denture base acrylic resins Materials (Basel) 2017;10(8):1013 DOI: 10.3390/ma10081013
Mahajan R, Kumar V, Nair KV, Babaji P Effect of microwave sterilization on flexural strength and hardness of heat-cured acrylic resins J Contemp Dent Pract 2016;17(9):733-38 DOI: 10.5005/jp-journals-10024-1917
Neppelenbroek KH, Pavarina AC, Vergani CE, Giampaolo ET, Machado AL Hardness of heat-polymerized acrylic resins processed in metallic and plastic flasks Braz Dent J 2005;16(2):109-15 DOI: 10.1590/S0103-64402005000200004
Saavedra G, Neppelenbroek KH, Vergani CE, Mesquita MF, Giampaolo ET Hardness and impact strength of heat-polymerized acrylic resins: Effect of water bath and microwave post-polymerization treatments J Prosthodont 2007;16(3):263-69 DOI: 10.1111/j.1532-849X.2007.00201.x
Davi LR, Neppelenbroek KH, Vergani CE, Miani PK, Machado AL Effect of post-polymerization heat treatments on the mechanical properties of acrylic resins Braz Dent J 2009;20(3):205-10 DOI: 10.1590/S0103-644020