Comparison of Mean Dimensional Changes in Acrylic Resin Specimen Disinfected with Wet Versus Dry Microwave Cycles at Different Time Intervals

Main Article Content

Faizan Malik
Syed Nasir Shah
Mohammad Ali Chughtai
Ehtesham Khan
Mariya Khalid
Hamad Ishtiaq Mian

Abstract

Objective: To determine the mean dimensional changes in acrylic resin specimens disinfected with wet and dry microwave cycles for disinfection.


Methodology: Acrylic resin specimens were fabricated using a stainless-steel mold measuring 64 x 10 x 3.3 mm in length, width, and thickness, respectively, according to ISO1567 standards. The acrylic resin specimens were measured using digital Vernier calipers and was then divided into ten groups through lottery method. After completing microwave irradiation cycles, measurements of each specimen were recorded using digital Vernier caliper and compared with the readings recorded before microwave treatment, post-irradiation dimensions of acrylic resin specimens were documented on predesigned performa.


Results: All acrylic resin specimens exhibited approximately no dimensional changes in all recorded measurements after microwave irradiation cycles. The results were statistically non-significant, with all t-tests having values of p>0.05 for each measured distance between the points. No deformations were seen in all groups’ specimens except the greatest deformation, which was found in the specimens of group F; that also showed a little change in length.


Conclusion: It may be concluded that these tested acrylic resin specimens demonstrated no deformation under experimental conditions at 850 W of dry and wet microwave irradiations for 3, 6, 9, 12, and 15 minutes and can be considered a suitable method for acrylic denture disinfection.

Article Details

How to Cite
1.
Malik F, Nasir Shah S, Ali Chughtai M, Khan E, Khalid M, Mian HI. Comparison of Mean Dimensional Changes in Acrylic Resin Specimen Disinfected with Wet Versus Dry Microwave Cycles at Different Time Intervals. J Postgrad Med Inst [Internet]. 2025 Mar. 29 [cited 2025 Apr. 2];39(1). Available from: https://jpmi.org.pk/index.php/jpmi/article/view/3518
Section
Original Article

References

Aslanimehr M, Mojarad N, Ranjbar S, et al. In vitro comparison of the effects of microwave irradiation and chemical and mechanical methods on the disinfection of complete dentures contaminated with Candida albicans. Dent Res J 2018;15:340-6.

Angela T, Wahyuni S, Halim S. The effect of soaking heat-polymerized acrylic resin denture base in avocado seed extract (Persea americana Mill.) on the inhibition of denture-plaque microorganisms biofilm growth. F1000Research 2024;13:933.

Elhagali AF, Sharaf MY, El-Aziz ME, Ali Bayiumy AS, Refaei MA, Al-Agamy AH, et al. The effects of different chemical disinfectants on the strength, surface, and color properties of conventional and 3D-printed fabricated denture base materials. Prosthesis 2025;7(2):24.

Gad MA, Abdelhamid AM, ElSamahy M, Abolgheit S, Hanno KI. Effect of aging on dimensional accuracy and color stability of CAD-CAM milled and 3D-printed denture base resins: a comparative in-vitro study. BMC Oral Health 2024;24(1):1124.

Gandhi N, Daniel S, Benjamin S, et al. Evaluation of surface microhardness following chemical and microwave disinfection of commercially available acrylic resin denture teeth. J Clin Diagn Res 2017;11:87-91.

Elhmali HT, Radojevic V, Stajcic A, Petrovic M, Stojanovic DB, Vlahovic B, et al. Denture base poly (methyl methacrylate) reinforced with SrTiO3/Y2O3: structural, morphological and mechanical analysis. Polymer Compos 2025;1-10.

Kreve S, Dos Reis AC. Denture liners: a systematic review relative to adhesion and mechanical properties. Sci World J 2019;1-11.

Ahmed ES, Oudah LM. Acrylic resin denture base material enhancement by fiber, filler, and nano filler addition: a systematic review. Tikrit J Dent Sci 2024;12(1):11-20.

Rohrer MD, Bulard RA. Microwave sterilization. J Am Dent Assoc 1985;110:194-8.

Mojarad N, Khalili Z, Aalaei S. A comparison of the efficacy of mechanical, chemical, and microwave radiation methods in disinfecting complete dentures. Dent Res J 2017;14:131-6.

Jaiswal P, Pande N, Banerjee R, et al. Effect of repeated microwave disinfection on the surface hardness of a heat-cured denture base resin: an in vitro study. Contemp Clin Dent 2018;9:446-51.

Ibraheem EMA, Hammad HGH. Effect of commercially available denture adhesives on microhardness of a flexible denture base material. Open Access Maced J Med Sci 2019;7:862-8.

Polyzois GL, Zissis AJ, Yannikakis SA. The effect of glutaraldehyde and microwave disinfection on some properties of acrylic denture resin. Int J Prosthodont 1995;8(2):150-4.

Da Costa RMB, Venante HS, Pordeus MD, Chappuis-Chocano AP, Neppelenbroek KH, Santiago Júnior JF, et al. Does microwave disinfection affect the dimensional stability of denture base acrylic resins? a systematic review. Gerodontology 2022;39(4):339-47.

Wagner DA, Pipko DJ. The effect of repeated microwave irradiation on the dimensional stability of a specific acrylic denture resin. J Prosthodont 2015;24:25-31.

Ribeiro DG, Pavarina AC, Dovigo LN, et al. Denture disinfection by microwave irradiation: a randomized clinical study. J Dent 2009;37:666-72.

Bayraktar G, Guvener B, Bural C, et al. Influence of polymerization method, curing process, and length of time of storage in water on the residual methyl methacrylate content in dental acrylic resins. J Biomed Mater Res B Appl Biomater 2006;76:340-5.

Basso MFM, Giampaolo ET, Machado AL, et al. Evaluation of the occlusion vertical dimension of complete dentures after microwave disinfection. Gerodontology 2012;29:815-21.

Senna PM, Jose Da Silva W, Faot F, Antoninha Del Bel Cury A. Microwave disinfection: cumulative effect of different power levels on physical properties of denture base resins. J Prosthodont 2011;20(8):606-12.

Polychronakis N, Yannikakis S, Zissis A. The effect of repeated microwaving disinfection on the dimensional stability of acrylic dentures. Acta Stomatol Croat 2014;48:279-84.

Alkhodary M. The effect of two microwave energies on the linear dimensional changes of two heat cured acrylic resin thicknesses. Egypt Dent J 2015;60(4):1-9.

Consani RLX, Mesquita MF, Zampieri MH, et al. Effect of the simulated disinfection by microwave energy on the impact strength of the tooth/acrylic resin adhesion. Open Dent J 2008;2:13-7.

Augusto Brondani M, Samim F, Feng H. A conventional microwave oven for denture cleaning: a critical review: microwave and dentures. Gerodontology 2012;29:6-15.

Most read articles by the same author(s)